• 1.01 MB
  • 2022-04-22 11:30:55 发布

某四星级宾馆给排水设计【毕业论文】

  • 45页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'本科毕业论文目录本科毕业论文(20届)某四星级宾馆给排水设计专业:建筑环境与设备工程 本科毕业论文目录目录摘要………………………………………………………………………………..……………….Ⅰ1.设计说明书………………………………………………………………………………………...11.1给水工程………………………………………………………………………………….......11.2排水工程……………………………………………………………………………………....21.3消防给水工程………………………………………………………………………………....31.4自动喷水灭火系统……………………………………………………………………………31.5室内热水工程………………………………………………………………………….…...…42.设计计算书………………………………………………………………………………………...42.1给水系统……………………………………………………………………………………....42.2室内热水系统………………………………………………………………………………..132.3生活排水系统水力计算…………………………………………………………………..…192.4雨水排水系统水力计算……………………………………………………………………..322.5消防系统………...………………………………………………………………………..…33设计小结………………………………………………………………………………………...….40参考文献………………………………………………………………………………………..…41译文……………………………………………………………..……………………………...…...42 本科毕业论文摘要摘要本设计的内容为九层酒店的给排水、雨水、热水、消防设计。该高层建筑为地上九层,地下一层。该建筑高度30m,建筑总面积约13824m2。生活给水系统采用变频泵给水方式。本建筑分区,从地下一层至地上三层采用市政管网供水,地上四层至九层采用变频泵供水。该方案供水安全可靠,投资及维护费用低。同时,水泵出水量稳定,能保持在高效区运行。排水系统采用宾馆客房合流排放,厨房废污分流排放。生活污水经室外化粪池处理后排至城市排水管网。屋面雨水排水系统采用外排水系统,因为此建筑为四星级宾馆,为保证建筑外观美丽,雨水管外包由后期装修设计完成。室内消火栓系统不分区,采用水箱和水泵联合供水的临时高压给水系统,并设有消防和生活共用水箱一个。消防给水系统管道采用独立设置,并且竖向成环。该建筑全楼均设自动喷水灭火系统,采用玻璃球闭式标准喷头。该系统管道采用独立设置,并且竖向成环。消防用水采用水箱和水泵联合供水方式。[关键词]建筑给水;建筑排水;消防系统;自喷系统 本科毕业论文摘要Afour-starhoteldrainagedesign[Abstract]Thisdesigncontentforninefloorshotelwatersupplyanddrainage,rain,hotwater,firefightingdesign.Thehigh-risebuildingforthegroundninefloors,undergroundlayer.Thisbuildingheight,atotalconstructionareaofabout13824m2aswell.Thedrinkingwatersystemusesofvariablefrequencypumpwater-supplymodes.Thisbuildingpartitions,fromundergroundlayertothegroundbymunicipalpipelinethreelayers,thegroundwaterfourfloortotheninthflooradoptsinvertertothewatersupplypump.Drainagesystemuseshotelroom,kitchenwastepollutiondischargeconfluentshuntemissions.Sewagetreatmentbacktotheoutdoorseptictankofurbandrainagepipelines.Roofrainwaterdrainagesystemadoptsthedrainagesystem,becausethebuildingforfour-starhotel,toensurethearchitecturalappearancebeautiful,decorateadesignbylatestormseweroutsourcingfinish.Indoorfirehydrantsystem,thecisternandnotdivisionofwatersupplypumphigh-pressurewatertemporaryjointsystem,andisequippedwithfireandlifecommontanka.Firewatersystem,andsetupindependentlypipelineinaverticalcyclization.Allthisbuildinghastheautomaticsprinklersystem,usesglassballclosedstandardsprinkler.Thissystempipeadoptindependentsetting,andverticalcyclization.Firewatersupplypumpadoptcisternandjointway.[KeyWords]Architecturalpipe;Buildingdrainage;Firecontrolsystem;Sincethesprinklersyste 本科毕业论文正文1.设计说明书1.1给水工程1.1.1设计资料根据设计资料,本建筑为某城市新建一座四星级宾馆,地下一层,地上九层,建筑高度约30m,建筑面积约13824m2,室外给水管网供水水压为0.3MPa。一到三层层高4.5米,其余标准层层高3.3米。1.1.2设计原则在设计中遵循以下几点原则:保障用水的安全可靠;设备及管道的布置尽量简洁、集中,以便于检修;管道及设备的布置尽量便于装修,使宾馆美观舒适。1.1.3方案比选方案一:无分区无水箱的供水方式,本方案采用多台水泵并联,根据水泵出水量或水压调节水泵运行台数。方案示意图如下:图1—1方案一示意图优点:供水较可靠,设备布置较集中,便于维护和管理,不占用建筑上层使用面积。缺点:水泵型号和数量比较多,投资较大,水泵控制调节比较麻烦,管道布置较复杂。方案二:设水泵和水箱的给水方式在地下室设置水池,由水泵将水池中水供至屋顶水箱,水池水源来自市政管网供水。其方案示意图如下:40 本科毕业论文正文图1—2方案二示意图优点:水泵能及时向水箱供水,可缩小水箱容积,又因水箱有调节作用,水泵出水量稳定,能保持在高效区运行。缺点:可能造成二次污染,增加建筑荷载。方案三:变频泵调速供水方式优点:不设置屋顶水箱,减小占地面积与建筑荷重,无二次污染供水水质好,设备便于自动控制,管理简便,控制精度高运行可靠;水泵可以软启动,降低了对电网供电量的需求,减少了水泵机组的机械冲击和磨损及水泵切换时的震荡现象因而延长了水泵的寿命;设备一般为一体化装置,体积小,占地少。缺点:不能满足消防贮水量,存在小流量和零流量的供水问题;一次性投入价格较高。考虑到宾馆对环境卫生的要求,本次设计中采用变频泵供水方式供水。考虑到尽量利用市政管网水压力,并且方便管理,节省电耗等因素,将宾馆给水分为两个区,低区为1至3层,由市政管网供水,高区为4至9层,由变频水泵供水。[1]1.1.4室内给水系统组成整个系统包括引如管、水表节点、给水管网和附件等,此外,还包括高区所需的地下贮水池、加压泵、屋顶水箱以及相配套的设备等。1.2排水工程1.2.1方案选择生活污水直接排至城市排水管网。地下室排水经污水泵提升后排至室外。本建筑属高层建筑,卫生器具较多,排水量较大。为防止水封破坏,排水立管采用伸顶通气。本建筑属四星级宾馆,对卫生标准要求较高,采用生活污水与生活废水分流的排水系统。因考虑实际工程需要客房及公共卫生间的生活污水及废水合流排放。[1]1.2.2排水系统的组成40 本科毕业论文正文排水系统包括以下几部分:卫生器具:室内排水系统的起点;横支管:将卫生器具排出的污水引入立管;立管:接纳横支管污水并将其排到干管或排出户外;横干管:接纳室内数根排水立管的污水,并将其引入排出管的管段;通气管:排出有害气体,平衡压力,防止水封破坏;排出管:接纳横干管的污水,将其排出室外;清通设备:疏通排水管;抽升设备和局部处理构筑物。[2]1.2.3屋面雨水排水系统的选型根据该建筑物的性质和雨水排水的要求,本设计采用重力流排水系统。因为建筑是四星级宾馆,考虑美观要求雨水管布置位置应美观大方,便于将来装修设计。1.3消防给水工程1.3.1室内消火栓系统消火栓的布置必须保证两股水柱能同时达到室内的任何一个部位,每股水柱的流量不小于30.00L/s,消火栓保护半径为27.1m。消火栓应设在使用方便的走道内,宜靠近疏散方便的通道口处、楼梯间内。消火栓口离地面距离为1.1m,栓口出水方向宜向下或与设置消火栓的墙面垂直。[2]1.3.2消防水池规范规定,不允许消防水泵直接从市政供水管网直接抽水。这样就需要设计消防水池以提供消防用水。1.3.2消防水泵和消防水泵房消防水泵在临时高压消防给水系统中设置,火灾时启动,用以保证消防所需的压力和水量。消防水泵采用清水离心泵。水泵出水量不小于所计算的消防用水量;水泵扬程在满足消防用水量的情况下,保证系统最不利点消防设备所需水压。消火栓消防水泵按一用一备设计,两台泵的基本性能及工作能力完全相同。每台水泵都有独立的吸水管。[3]1.3.3消防水箱消防水箱的主要作用是供给高层建筑初起火灾时的消防用水量,并保证相应的水压要求。消火栓消防水箱设置在屋顶水箱间,保消防初期火灾的用水可靠性,采用重力自流的水箱,消防水箱贮水量根据计算确定,水箱容积满足规范要求:一类建筑不小于18m3。1.3.4消防水泵接合器水泵结合器是消防车往室内管网供水的接口。水泵结合器一端由室内消火栓给水管网最底层引至室外,另一端进口可供消防车或移动水泵站加压向室内管网供水。1.4自动喷水灭火系统自动喷水灭火系统是一种在发生火灾时,能自动喷水灭火并同时发出火警信号的灭火系统。这种灭火系统具有很高的灵敏度和灭火成功率,是扑灭建筑初期火灾非常有效的一种灭火设备。[3]1.4.1闭式喷头40 本科毕业论文正文闭式喷头是闭式自动喷水灭火系统的关键设备,它通过热敏感释放机构的动作而喷水,喷头由喷水口、温感释放器和溅水盘组成。[3]1.4.2报警阀门报警阀又称检查信号阀或控制信号阀,是自动喷水灭火系统的重要部件之一,平时用于检查火警信号,发生火灾后发出火警信号,不同类型的自动喷水灭火系统,安装不同结构的报警阀。湿式报警阀安装在湿式自动喷水灭火系统的立管上,选择导阀型湿式报警阀。1.4.3水流指示器水流指示器是一种监测器,用它来监测系统所处的工作状态,减少失败率,提高系统灭火能力。1.4.4末端试水装置末端试水装置由试水阀、压力表以及试水接头组成。为了检验系统地可靠性,测试系统能否在开放一只喷头的最不利条件下可靠报警并正常启动,在每个报警阀组控制的最不利点喷头处,设计了末端试水装置,其他防火分区、楼层的最不利点喷头处,均设置了直径为25mm的试水阀。试水接头出水口的流量系数,等于同楼层或防火分区内的最小流量系数喷头。1.4.5自动排气阀自动喷水灭火系统的最高处设置自动排气阀,排除系统内积存的气体,保证系统正常工作。1.5室内热水工程1.5.1系统选择该建筑的功能决定了其对热水供应要求较高,所以采用全天热水供应系统,为保证任何时刻均达到设计水温(出水温度60℃,最不利点温度为55℃),采用机械全循环系统,这种循环系统可以随时迅速获得热水,使用方便。适用于对热水供应要求高的建筑。考虑到国内目前多数方式均为立管循环,既经济又实用,故采用。加热设备选用空气源热泵,这种设备既节约成本又环保。1.5.2系统组成由加热器、配水管网、回水管网、循环水泵及附件等组成[3]。2.设计计算书2.1给水系统2.1.1最高日,最大时用水量最高日,最大时用水量计算,按照建筑给水排水设计规范(GB50015-2003)(2009年版)进行计算各用水部位统计结果如下:40 本科毕业论文正文表2—1最高日,最大时用水量计算表用水部位用水标准单位数量用水时间变化系数用水量(立方米)最大日最大时平均时宾馆客房300L/床·d288242.286.47.923.6宾馆客房90L/人·d100242.290.830.38餐饮业10L/顾客·次50081.350.810.63未预见水按本表以上项目的10%计10.040.960.46合计110.4410.515.062.1.2消防水箱计算高位水箱消防贮水量的容积按贮存10min的室内消防用水量计算,消火栓用水量qxb为30L/s。则消防水箱容积:Vx=qxb×Tx×60/1000=30×10×60/1000=18m3。自喷系统储水量的容积计算:由《自喷设计规范》知本建筑属于中危险Ⅰ级,自喷强度为6L/min·m2喷头工作压力为0.10MPa,作用面积为160m2。则喷淋水箱容积:Vzp=P×S×T/1000=6×160×10/1000=9.6m3。水箱净容积:V=Vx+Vzp=18+9.6=27.6m3本设计水箱形状选用矩形玻璃钢保温水箱,根据水箱的有效容积27.6m3,其构造尺寸定为L×B×H=4.8m×3.4m×2.0m=32.6m3。水箱的附件有进水管、出水管、溢流水管、泄水管、通气管、水位信号装置、人孔、仪表孔。本设计中,水箱供给消火栓和自动喷水灭火系统在火灾初期10min的消防用水量,因此要有消火栓和自动喷水灭火系统两个出水管,均从箱底接出。2.1.3贮水池计算因为市政给水管不允许水泵直接从管网抽水,故设生活消防共用贮水池,其容积为:V=Vt+Vx+Vzp式中:Vt—生活调节水量;Vx—消防贮备水量;Vzp—自喷贮备水量;生活调节水量按建筑最高日用水量的20%估算。40 本科毕业论文正文即:Vt=110.4×20%=22.08m3消防贮水按满足火灾延续时间二小时内的室内消防用水量来计算。即:Vx=30×2×60×60/1000=216.00m3自喷贮备水量按满足火灾延续时间一小时内的室内消防用水量来计。即:Vzp==57.60m3贮水池的有效容积为:V=22.08+216.00+57.60=295.68m3取贮水池总容积为300m3。由此将贮水池的尺寸定义为:L×B×H=12×10.0×2.5=300m3。2.1.4生活给水系统水力计算采用当量法计算,计算原理参照《建筑给水排水设计规范GB50015-2003》(2009年版),采用公共建筑采用当量法。[6]基本计算公式:式中:qg—计算管段的给水设计秒流量(L/s);Ng—计算管段的卫生器具给水当量总数;α—根据建筑物用途而定的系数;建筑类型:客运站、航站楼、会展中心、公共厕所,α值为:3;宿舍(Ⅰ、Ⅱ类)、旅馆、招待所、宾馆,α值为:2.5。图2—1给—1A示意图40 本科毕业论文正文计算结果:表2—2给—1A计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.10.130.5200.030.540.0052-30.10.910.5200.030.540.0253-40.20.911250.0350.680.034-50.30.341.5250.0741.010.0255-60.30.71.5250.0741.010.056-70.32.9051.5250.0741.010.2157-80.50.572.5320.0581.040.0358-92.42.794630.0391.280.119-102.610.35.5630.0461.390.01510-112.610.335.5630.0461.390.01512-30.10.130.5200.030.540.0054-130.10.130.5200.030.540.00514-150.10.0850.5200.030.540.00515-160.10.570.5200.030.540.01516-170.20.171250.0350.680.0057-170.20.31250.0350.680.0118-190.10.1150.5200.030.540.00519-200.10.470.5200.030.540.01520-210.10.550.5200.030.540.01521-221.30.91500.0381.10.03522-231.930.481.5630.0261.030.0158-231.930.71.5630.0261.030.0224-250.10.1150.5200.030.540.00525-260.10.540.5200.030.540.01526-270.10.550.5200.030.540.01527-281.30.91500.0381.10.03528-291.930.481.5630.0261.030.01529-301.930.71.5630.0261.030.029-301.930.521.5630.0261.030.01531-320.10.0850.5200.030.540.00532-160.10.570.5200.030.540.01533-211.20.1850.5250.9684.060.1834-221.20.1850.5250.9684.060.1835-271.20.250.5250.9684.060.2436-281.20.250.5250.9684.060.2440 本科毕业论文正文图2—2给—2(3)A示意图计算结果:图2—3给—2(3)A计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.11.050.5200.030.540.032-30.10.730.5200.030.540.023-40.40.662320.0380.830.0254-50.80.5254400.0471.060.0256-70.20.8151250.0350.680.037-30.30.41.5250.0741.010.038-90.11.2350.5200.030.540.0359-100.10.720.5200.030.540.0210-40.40.1852320.0380.830.00511-70.10.10.5200.030.540.00512-130.20.8851250.0350.680.0310-130.30.181.5250.0741.010.01514-130.10.10.5200.030.540.00540 本科毕业论文正文图2—3给—4A示意图计算结果:表2—4给—4A计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.21.051250.0350.680.0352-30.20.731250.0350.680.0253-40.40.4952320.0380.830.024-50.40.5252320.0380.830.026-70.10.960.5200.030.540.037-30.20.091250.0350.680.0058-70.10.190.5200.030.540.005图2—4给水立管1示意图40 本科毕业论文正文计算结果:表2—5给水立管1计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.80.54400.0471.060.022-30.83.34400.0471.060.153-41.413.38500.0451.20.154-51.733.312500.0651.460.225-623.316630.0281.070.096-72.242.620630.0341.20.098-30.80.54400.0471.060.029-40.80.54400.0471.060.0210-50.80.54400.0471.060.0211-60.80.54400.0471.060.02图2—5给水立管2示意图计算结果:表2—6给水立管2计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.80.54400.0471.060.022-30.83.34400.0471.060.153-41.413.38500.0451.20.154-51.732.612500.0651.460.176-30.80.54400.0471.060.027-40.80.54400.0471.060.0240 本科毕业论文正文图2—6给水干管1示意图计算结果表2—7给水干管1计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-22.240.9620630.0341.20.032-32.247.6520630.0341.20.263-43.460.4544750.0191.040.014-545.4564750.0251.210.145-64.584.6584750.0321.380.156-75.17.11104750.0391.540.287-86.41.5164900.031.450.049-33.460.9524750.0191.040.0210-42.240.9520630.0341.20.0311-122.240.9520630.0341.20.0312-52.242.6520630.0341.20.096-132.240.7320630.0341.20.0314-152.242.1620630.0341.20.0715-162.245.5620630.0341.20.1916-173.1611.140750.0160.950.187-173.874.4360750.0231.170.118-162.240.7320630.0341.20.0319-172.240.7320630.0341.20.0340 本科毕业论文正文图2—7给水干管2示意图计算结果:表2—8给水干管2计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-22.241.120630.0341.20.042-32.240.7820630.0341.20.033-43.467.3244750.0191.040.144-545.2264750.0251.210.135-64.584.9584750.0321.380.166-75.116.07104750.0391.540.637-861.32144900.0261.360.039-33.461.124750.0191.040.0210-42.241.120630.0341.20.0411-122.242.8820630.0341.20.112-52.241.120630.0341.20.046-132.240.9720630.0341.20.0314-152.242.3920630.0341.20.0815-162.245.5520630.0341.20.197-163.166.1340750.0160.950.117-162.240.9720630.0341.20.03室内所需水压计算:H=H1+H2+H3式中:H—建筑内给水系统所需的水压,mH2O;H1—引入管起点至配水最不利点的位置高度所要求的静水压,mH2O;H2—引入管起点至配水最不利点的给水管路即计算管路的沿程与局部水头损失之和,mH2O(局部水头损失按沿程损失的30%计算);H3—配水最不利点所需的流出水头,kPa。[7]40 本科毕业论文正文则H=33+7+0.5=40.5(mH2O)水泵选型:KQG-2045,流量20m3/h,扬程45m。共两台,一用一备。为防止出户压力过大,在每个客房的进户管中安装压力调节阀。2.2室内热水系统2.2.1热水量计算式中:Qh—最大小时热水用量;m—用水计算单位数(取244床);qr—热水用水定额(取200L/床﹒d);T—热水供应时间(取24小时);Kh—小时变化系数(取4.58);则:2.2.2耗热量计算式中:Q—设计小时耗热量(W);C—水的比热(J/(Kg·℃)为4.187KJ/(Kg·℃);Qh—设计小时热水用量;tr—热水温度为60℃;tL——冷水温度为5℃;则:2.2.3加热设备及水箱选型选用6台高温直热式空气能热水机组RSJ-770。该机组流量为2m3/h,制热量为77KW。为保证宾馆热水供应外加一台辅助电加热器SDS-100/S-A,该辅助电加热功率为100KW。加热水箱选用两个10T的不锈钢水箱作为热水的储存水箱。[8]40 本科毕业论文正文2.2.4管网水力计算采用当量法计算。式中:qg—计算管段的给水设计秒流量(L/s);Ng—计算管段的卫生器具给水当量总数;α—根据建筑物用途而定的系数取2.5;图2—8热给—2(3)A示意图计算结果:表2—9热给—2(3)A计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.151.240.75200.0640.810.082-30.150.720.75200.0640.810.053-40.350.661.75250.0991.180.074-50.70.523.5400.0360.930.026-30.21.061250.0350.680.047-80.151.050.75200.0640.810.078-90.150.730.75200.0640.810.059-40.350.191.75250.0991.180.0210-90.21.221250.0350.680.0440 本科毕业论文正文图2—9热给—4A示意图计算结果:表2—10热给—4A计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.151.050.75200.0640.810.072-30.150.730.75200.0640.810.053-40.350.491.75250.0991.180.054-50.350.521.75250.0991.180.056-30.21.051250.0350.680.04图2—10热水立管1示意图40 本科毕业论文正文计算结果:表2—11热水立管1计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.70.53.5400.0360.930.022-30.73.33.5400.0360.930.123-41.323.37500.041.120.134-51.623.310.5500.0581.370.195-61.873.314630.02510.086-72.093.2117.5630.031.120.18-30.70.53.5400.0360.930.029-40.70.53.5400.0360.930.0210-50.70.53.5400.0360.930.0211-60.70.53.5400.0360.930.02图2—11热水立管2示意图计算结果:表2—12热水立管2计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.350.51.75250.0991.180.052-30.353.31.75250.0991.180.333-40.73.33.5400.0360.930.124-51.053.35.25500.0260.890.095-61.323.37500.041.120.1340 本科毕业论文正文6-71.483.228.75500.0491.250.168-30.350.51.75250.0991.180.059-40.350.51.75250.0991.180.0510-50.350.51.75250.0991.180.0511-60.350.51.75250.0991.180.05图2—12热水立管3示意图计算结果:表2—13热水立管3计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-20.70.53.5400.0360.930.022-30.73.33.5400.0360.930.123-41.323.37500.041.120.134-51.622.610.5500.0581.370.155-61.621.510.5500.0581.370.096-71.627.210.5500.0581.370.428-30.70.53.5400.0360.930.029-40.70.53.5400.0360.930.0240 本科毕业论文正文图2—13热水干管示意图计算结果:表2—14热水干管计算表管段名称管道流量L/s管长m累计当量标注管径水力坡降mH2O/m流速m/s沿程损失mH2O1-22.096.6217.5630.031.120.22-32.966.1635750.0140.890.093-43.620.2552.5750.0211.090.014-53.977.8563750.0251.20.195-64.490.2980.5750.0311.350.016-74.775.7791750.0341.440.27-85.215.81108.5750.0411.570.248-95.4111.37117.25750.0441.630.59-105.811.1134.75750.051.750.5510-116.175.48152.25900.0281.40.1511-126.515.1169.75900.0311.470.1612-136.710.38180.25900.0321.520.0113-147.037.82197.75900.0351.590.2714-157.220.31208.25900.0371.630.0115-167.516.71225.75900.041.70.2716-177.81.39243.25900.0431.770.0617-188.075.65260.751100.0191.270.1118-198.072.9260.751100.0191.270.0520-212.090.5517.5630.031.120.022-212.091.9417.5630.031.120.0640 本科毕业论文正文3-222.090.5417.5630.031.120.024-231.620.5410.5500.0581.370.035-242.090.5517.5630.031.120.026-251.620.5510.5500.0581.370.0326-272.090.5517.5630.031.120.027-272.092.0417.5630.031.120.068-281.480.648.75500.0491.250.039-292.090.6417.5630.031.120.0210-302.090.6417.5630.031.120.0231-322.090.617.5630.031.120.0232-112.092.5917.5630.031.120.0833-121.620.610.5500.0581.370.0334-132.090.617.5630.031.120.0235-141.620.610.5500.0581.370.0336-152.090.617.5630.031.120.0237-162.094.9317.5630.031.120.1538-172.090.617.5630.031.120.02冷水供应所需水压计算:H=H1+H2+H3式中:H—建筑内给水系统所需的水压,mH2O;H1—引入管起点至配水最不利点的位置高度所要求的静水压,mH2O;H2—引入管起点至配水最不利点的给水管路即计算管路的沿程与局部水头损失之和,mH2O;H3—配水最不利点所需的流出水头,kPa。H=33+6+0.5=39.5(mH2O)水泵选型:KQG-1040,流量10m3/h,扬程40m。共两台;一用一备。热循环泵:CR2-5,Q=2m3/h,P=7m,N=0.1KW;两用一备。循环加热泵:Q=10m3/h,P=18m,N=1.5KW。2.3生活排水系统水力计算计算原理参照《建筑给水排水设计规范GB50015-2003》(2009年版),采用公共建筑采用当量法。基本计算公式40 本科毕业论文正文式中:qp—计算管的排水设计秒流量(L/s);Np—计算管段的卫生器具排水当量总数;qmax—计算管段上最大一个卫生器具的排水流量(L/s);α—根据建筑物用途而定的系数取2.0。2.3.1排水定额本建筑所采用的卫生器具的流量、当量和排水管的管径、最小坡度列表:表2—15卫生器具排水定额表序号卫生器具名称排水流量(L/s)当量排水管管径(mm)最小坡度1小便器0.10.3500.0252大便槽2.57.540~500.023大便器1.54.51000.0124洗脸盆0.250.7532~500.022.3.2污水、废水系统为保证管道系统有良好的水力条件,稳定管内气压,防止水封破坏,保证良好的室内环境卫生,在排水管道的设计中,必须满足下列规定:a.横管充满度,建筑内部排水横管按非满流设计,以便使污废水释放出的有毒有害气体能自由排出,调节排水管道系统内的压力,排水管道的最大设计充满度见下表:表2—16排水管道最大设计充满表排水管道名称排水管道管径(mm)最大计算充满度(以管径计)生活污水排水管150以下0.5生活废水排水管150~2000.6自净流速,污水中含有固体杂质,如果流速过小,固体物会在管内沉淀,减小过水断面积,造成排水不畅或堵塞管道,为此规定了一个最小流速,即自净流速,建筑内部排水横管自净流速见下表:40 本科毕业论文正文表2—17建筑内部排水横管自净流速表污废水类别生活污水在下列管径时(mm)D<150D=150D=200自净流速(m/s)0.60.650.7管道坡度,污废水中含有的污染物越多,管道坡度应越大,塑料排水管坡度见下表:表2—18塑料排水管坡度表管径(mm)通用坡度最小坡度500.0260.012750.0260.0071100.0260.0041600.0260.002最小管径,在本设计中应注意大便器没有十字栅栏,同时排水量大且猛,所以,凡连接大便器的支管,即使仅有1个大便器,其最小管径均为100mm。小便器冲洗不及时,尿垢积聚,堵塞管道,因此,小便器和连接3个及3个以上小便器的排水支管管径不小于75mm。b.立管排水立管按通气方式分为:普通伸顶通气、专用通气立管通气、特制配件伸顶通气和不通气四种情况。四种情况的排水立管最大允许通水能力见下表:表2—19排水立管最大允许通水能力表通气情况立管工作高度(m)管径(mm)5075100125150普通伸顶通气-12.54.5710设有专用通气立管通气--591425特制配件伸顶通气---6913无通气管≤211.73.830.641.352.440.50.921.7650.40.71.3660.40.5170.40.50.76≥80.40.50.6440 本科毕业论文正文在确定立管管径时,还需做到排水立管管径不得小于横支管管径,多层住宅厨房间排水立管管径不应小于75mm,厕所间排水立管管径不应小于100mm。2.3.3水力计算计算原理参照《建筑给水排水设计规范GB50015-2003》(2009年版),采用公共建筑采用当量法。基本计算公式式中:qp—计算管的排水设计秒流量(L/s);Np—计算管段的卫生器具排水当量总数;qmax—计算管段上最大一个卫生器具的排水流量(L/s);α—根据建筑物用途而定的系数取2.0。图2—14污—1A示意图计算结果:表2—20污—1A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.10.3500.0260.960.152-30.20.6500.0260.960.223-40.30.9500.0260.960.2740 本科毕业论文正文4-50.31.4500.0260.960.27图2—15污—1B示意图计算结果:表2—21污—1B计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.10.3500.0260.960.152-30.10.3500.0260.960.153-40.20.6500.0260.960.224-52.78.11100.0261.530.325-63.4515.61100.0261.530.376-73.5820.11100.0261.530.378-300500.026009-30.10.3500.0260.960.1510-61.54.51100.0261.530.2440 本科毕业论文正文图2—16污—1C示意图计算结果:表2—22污—1C计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-2001100.026002-32.57.51100.0261.530.313-43.43151100.0261.530.374-53.5619.51100.0261.530.375-63.57201100.0261.530.377-41.54.51100.0261.530.24图2—17污—2A示意图40 本科毕业论文正文计算结果:表2—23污—2A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.250.75500.0260.960.242-30.250.75500.0260.960.243-40.250.75500.0260.960.244-51.54.51100.0261.530.245-61.551100.0261.530.246-72.1881100.0261.530.297-82.46161100.0261.530.319-613750.0261.260.2910-110.250.75500.0260.960.2411-120.250.75500.0260.960.2412-130.250.75500.0260.960.2413-141.54.51100.0261.530.2414-151.551100.0261.530.2415-162.1881100.0261.530.2916-172.1881100.0261.530.297-172.1881100.0261.530.2918-1513750.0261.260.2919-174.2452.51100.0261.530.41图2—18污—3A示意图40 本科毕业论文正文计算结果:表2—24污—3A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.250.75500.0260.960.242-30.250.75500.0260.960.243-40.250.75500.0260.960.244-51.755.251100.0261.530.265-61.755.751100.0261.530.266-72.218.751100.0261.530.297-84.7487.51100.0261.530.449-613750.0261.260.2910-110.250.75500.0260.960.2411-120.250.75500.0260.960.2412-130.250.75500.0260.960.2413-141.755.251100.0261.530.2614-151.755.751100.0261.530.2615-162.218.751100.0261.530.297-164.2452.51100.0261.530.4117-1513750.0261.260.29图2—19污—4A示意图计算结果:表2—25污—4A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.250.75500.0260.960.242-30.250.75500.0260.960.243-40.250.75500.0260.960.244-51.755.251100.0261.530.2640 本科毕业论文正文5-61.755.751100.0261.530.266-72.218.751100.0261.530.297-82.218.751100.0261.530.298-94.2452.51100.0261.530.419-104.7487.51100.0261.530.4411-613750.0261.260.2912-130.250.75500.0260.960.2413-140.250.75500.0260.960.2414-150.250.75500.0260.960.2415-161.755.251100.0261.530.2616-171.755.751100.0261.530.269-172.218.751100.0261.530.2918-1713750.0261.260.29图2—20污—5A示意图计算结果:表2—26污—5A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.250.75500.0260.960.242-30.250.75500.0260.960.243-40.250.75500.0260.960.244-51.755.251100.0261.530.2640 本科毕业论文正文5-61.755.751100.0261.530.266-72.218.751100.0261.530.297-84.2452.51100.0261.530.419-613750.0261.260.2910-114.2452.51100.0261.530.4111-74.2452.51100.0261.530.41图2—21污—4’A示意图计算结果:表2—27污—4’A计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20.250.75500.0260.960.242-30.250.75500.0260.960.243-40.250.75500.0260.960.244-51.755.251100.0261.530.265-61.755.751100.0261.530.266-72.218.751100.0261.530.297-82.218.751100.0261.530.298-92.218.751100.0261.530.299-102.517.51100.0261.530.3111-613750.0261.260.2912-84.2452.51100.0261.530.4113-140.250.75500.0260.960.2414-150.250.75500.0260.960.2415-160.250.75500.0260.960.2440 本科毕业论文正文16-171.755.251100.0261.530.2617-181.755.751100.0261.530.269-182.218.751100.0261.530.2919-1813750.0261.260.29图2—22污水立管1示意图计算结果:表2—28污水立管1计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20011000.9602-32.517.511001.530.313-43.923511001.530.394-54.2452.511001.530.415-64.2452.511001.530.416-74.2452.51100.0261.530.417-84.2452.511001.530.418-94.2452.511001.530.419-104.2452.51100.0261.530.4111-22.517.51100.0261.530.3112-32.517.51100.0261.530.314-132.517.51100.0261.530.3140 本科毕业论文正文5-142.517.51100.0261.530.318-152.517.51100.0261.530.31图2—23污水立管2示意图计算结果:表2—29污水立管2计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-20011000.9602-32.517.511001.530.313-43.923511001.530.394-54.2452.511001.530.415-64.517011001.530.426-74.51701100.0261.530.427-84.517011001.530.428-94.7487.511001.530.449-105.89103.116002.010.2710-116.06118.716002.010.2811-126.06118.71600.0262.010.282-132.517.51100.0261.530.313-142.517.51100.0261.530.314-152.517.51100.0261.530.315-162.517.51100.0261.530.318-172.517.51100.0261.530.3140 本科毕业论文正文9-183.4515.61600.0262.010.2110-193.4515.61600.0262.010.21图2—24污水立管3示意图计算结果:表2—30污水立管3计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-2005000.9602-30.31.45000.960.273-40.62.85000.960.394-50.62.8500.0260.960.396-20.31.4500.0260.960.277-30.31.4500.0260.960.2740 本科毕业论文正文图2—25污水立管4示意图计算结果:表2—31污水立管4计算表管段名称管道流量L/s累计当量公称直径坡度流速m/s充满度1-2001600002-33.572016002.010.213-45.094016002.010.264-55.09401600.0262.010.266-23.57201600.0262.010.217-33.57201600.0262.010.212.3.4地下室排水地下室排水采用潜污泵,水泵流量根据地下室消防用水流量确定,扬程根据提水高度确定。2.4雨水排水系统水力计算根据该建筑物的性质和雨水排水的要求,本设计采用外排水系统。2.4.1设计暴雨强度q40 本科毕业论文正文设计暴雨强度公式中有设计重现期P和屋面集水时间t,2个参数。设计重现期应根据生产工艺及建筑物的性质确定,采用5年。由于屋面建筑面积较小,屋面集水时间应较短,因为我国推导暴雨强度公式所需实测降雨资料的最小时段为5min,所以屋面集水时间按5min计算。查资料得浙江舟山地区的q5=3.88L/s•100m2。2.4.2汇水面积屋面雨水汇水面积较小,一般以m2计算。屋面都有一定坡度,汇水面积不按实际面积计算,而是按水平投影面积计算。考虑到大风作用下雨水倾斜降落的影响,对于高出屋面的侧墙及窗井,应降其垂直墙面积的1/2计入屋面汇水面积。若高出屋面两侧为侧墙时以两侧端头联线面积的1/2计入汇水面积,三侧或三侧以上有侧墙时,也只按两侧计算。室内雨水管道采用UPVC管,在底层设检查口,每层设伸缩节。2.4.3水力计算式中:Q—屋面雨水设计流量;—径流系数,屋面取0.9;F—屋面汇水面积;q5—暴雨强度。在本工程中选中87式雨斗,管径选用100mm。查表得最大的泄流量为12L/s,从而计算出汇水面积F为:343m2。2.5消防系统2.5.1消火栓系统按规范要求,室内消防给水系统应与生活该水系统分开独立设置,室内消防给水管道应布成环状。室内消防给水环状管网的进水管和区域高压或临时高压给水系统的引入管不应少于两根,当其中一根发生故障时,其余的进水管或引入管应能保证消防用水量和水压的要求。消防竖管的布置,应保证同层相邻两个消火栓的水枪的充实水柱同时达到被保护范围内的任何部位。每根消防竖管的直径应按通过的流量经计算确定,但不应小于100mm。室内消火栓给水系统应与自动喷水灭火系统分开设置。室内消防给水管道应采用阀门分成若干独立段,阀门的布置,应保证检修管道时管闭停用的竖管不超过1根,当竖管超过4根时,可管闭不相邻的2根,阀门应有明显的启闭标志。[9]室内消火栓给水系统应设水泵接合器,水泵接合器的数量应按室内消防用水量经计算确定。每个水泵接合器的流量应按10~15L/s计算。40 本科毕业论文正文根据《高层民用建筑设计防火规范》,本设计中的室内消火栓用水量为30L/s,每根竖管最小流量15L/s,每支水枪最小流量5L/s。故本设计中的室内消火栓给水系统水泵接合器的数量为3个。水泵接合器应设在室外便于消防车使用的地点,距室外消火栓或消防水池的距离宜为15~40m,采用地上式水泵接合器;室外消防流量为40L/s,由于室外消火栓与水泵接合器要配合使用,故采用三个室外消火栓,型号为SS150—1.6地上式。消火栓应设在走道、楼梯附近等明显易于取用的地点,消火栓的间距应保证同层任何部位有两个消火栓的水枪充实水柱同时到达。[10]2.5.2消火栓保护半径计算本设计中采用的消火栓口径为65mm单栓口,水枪喷嘴口径19mm,充实水柱为12mH2O,采用麻质水带(衬胶)直径65mm,长度25m。消火栓保护半径按公式(R=C×Ld+h)计算:h=HSin45=10×0.71=7.1mR=C×Ld+h=0.8×25+7.1=27.1m式中:Ld—消火栓水龙带长度,取25.0m;C—保护系数,取0.8;h—为充实水柱水平投影长度;H—水枪充实水柱长:取10m;消火栓布置间距为S≤==24.7m其中b为消火栓的最大保护宽度,应为一个房间的长度加上走廊的宽度。2.5.3消火栓的设置本建筑总长48m,宽度32.4m。按规范要求,消火栓的间距应保证同层任何部位有两个消火栓的水枪充实水柱同时到达。据此,每一层布置6个消火栓,屋顶布置1个试验消火栓。消火栓均应布置在走道、楼梯附近等明显易于取用的地点。具体布置见平面图。消火栓口离地面高度为1.10m,栓口出水方向宜向下或与设置消火栓的墙面相垂直。[11]2.5.4消火栓给水系统计算消防给水管径确定,按照最不利点消防竖管和消火栓的流量分配要求,最不利消防竖管即:出水枪数为3支,相邻消防竖管,出水枪数为3支。次相邻消防管,出水强数为2支。所有消防立管管径统一取DN100mm(v=1.9m/s),所有消防横管管径统一取DN150mm。基本计算公式最不利点消火栓流量:40 本科毕业论文正文式中:qxh—水枪喷嘴射出流量(L/s)(依据规范需要与水枪的额定流量进行比较,取较大值);B—水枪水流特性系数;Hq—水枪喷嘴造成一定长度的充实水柱所需水压(mH2O)。最不利点消火栓压力:式中:Hxh—消火栓栓口的最低水压(0.010MPa);hd—消防水带的水头损失(0.01MPa);hq—水枪喷嘴造成一定长度的充实水柱所需水压(0.01MPa);Ad—水带的比阻;Ld—水带的长度(m);qxh—水枪喷嘴射出流量(L/s);B—水枪水流特性系数;Hsk—消火栓栓口水头损失,宜取0.02MPa。次不利点消火栓压力:式中:H层高—消火栓间隔的楼层高(m);Hf+j—两个消火栓之间的沿程、局部水头损失(m);次不利点消火栓流量:水龙带材料:衬胶水龙带长度:25m40 本科毕业论文正文水龙带直径:65mm水枪喷嘴口径:19mm充实水柱长度:10m图2—26消防系统图计算结果如下:表2—32消防系统计算表计算管段设计秒流量L/s管径DN(mm)流速m/s水力坡降1000i管长m沿程水损mh201~251000.65103.30.0032~3101001.336.53.30.0123~415.51002.0187.720.40.1794~515.51002.0187.716.50.1455~6311004.03350.814.80.5196~746.51006.03789.3151.1847~8621503.73176.615.70.2778~977.51504.44251.114.90.3749~1077.51504.44251.1401.004则消防管网入口点所需水压为:Hx=30+1.1+3.32+17+0.3×3.32=52.4mH2O取Hx=60mH2O则消防泵的流量为80L/s,扬程为60m。40 本科毕业论文正文2.5.5自动喷淋灭火系统水力计算计算原理参照《自动喷水灭火系统设计规范GB50084-2001》(2005年版)基本计算公式:喷头流量:式中:q—喷头处节点流量,L/min;P—喷头处水压(喷头工作压力)MPa;K—喷头流量系数;流速V:式中:Q—管段流量L/s;Dj—管道的计算内径(m);水力坡降:式中:i—每米管道的水头损失(mH20/m);V—管道内水的平均流速(m/s);dj—管道的计算内径(m),取值应按管道的内径减1mm确定。沿程水头损失:式中:L—管段长度m。局部损失(采用当量长度法):(当量)式中:40 本科毕业论文正文L(当量)—管段当量长度,单位m(《自动喷水灭火系统设计规范》附录C)总损失:终点压力:图2—27喷淋最不利点示意图计算结果如下:表2—33喷淋最不利点计算表管段起点压力mH2O管道流量L/s管长m当量长度管径mm水力坡降mH2O/m流速m/s损失mH2O终点压力mH2O1-21.00.423.20.6250.0770.790.291.292-31.290.420.381.5500.0020.201.33-131.190.460.690.6250.0910.860.121.313-41.30.882.013.6500.0090.410.051.344-141.160.451.460.6250.0890.850.181.344-51.341.330.693.7650.0050.380.021.375-151.250.470.690.6250.0960.880.121.375-61.371.82.73.7650.0090.510.061.436-161.30.480.690.6250.10.90.131.436-71.432.280.254.3650.0150.650.071.4917-186.011.030.460.6250.4621.940.496.518-196.51.030.590.8250.4621.940.647.1422-234.00.840.460.6250.3081.580.334.3323-194.330.840.110.8250.3081.580.284.6119-207.141.871.491.8320.3281.971.088.2220-218.221.870.370.9320.3281.970.428.637-218.631.872.581.4320.3281.971.39.947-81.494.152.424.6800.020.840.141.648-241.410.51.460.6250.1080.940.221.6340 本科毕业论文正文8-91.644.641.024.6800.0250.940.141.7825-265.7210.450.8250.4411.890.556.2732-264.00.840.250.8250.3081.580.324.3226-276.271.8432.1320.3191.951.637.933-274.00.840.450.6250.3081.580.324.3234-274.00.840.250.6250.3081.580.264.2627-287.93.520.963.1500.1381.660.568.4628-298.463.520.361.5500.1381.660.268.7129-308.713.523.991.5500.1381.660.769.4735-364.00.840.610.6250.3081.580.374.3736-304.370.842.121.2320.0660.890.224.5930-319.474.360.883.1500.2112.060.8410.3137-314.00.840.610.6250.3081.580.374.379-3110.315.21.863.7500.32.451.6711.989-101.789.850.714.6800.1131.980.62.3810-381.880.582.860.6250.1441.080.52.3710-112.3810.420.444.6800.1272.10.643.0211-392.770.70.610.6250.2131.320.263.0211-123.0211.120.874.6800.1442.240.793.81所选作用面积:160平方米;总流量:11.12L/s;平均喷水强度:6.04L/min·m2;入口压力:3.81米水柱;则喷淋管网入口点所需水压为;Hx=30+3.81+10+0.3×3.81=45.4mH2O;取Hx=50mH2O;则喷淋泵的流量为11.1L/s,扬程为50m。40 本科毕业论文设计小结设计小结在整个设计期间,通过资料的收集、整理、分析、设计计算、管路的设计以及说明书的撰写,我终于圆满完成了此次设计。通过本次设计,本人巩固了以前所学的知识,把所学的零星知识串成了一个整体;对给排水设计有了一个比较完整的认识和了解,并系统的掌握了设计的过程和方法。这次的设计可以说既巩固了所学知识,也培养了一种独立的能力。而值得一说的是,由于自己是初学设计,实践经验不足,在这个设计过程中遇到了不少的麻烦,其中就有其中就有那么几个:首先就是对于土建资料的查找,由于图纸中的一些资料不全面再加上自己不熟悉这方面,所以花了很长时间去找;再者就是管段的计算,如水管的计算,个人觉得这两方面都有点难度,有些知识是学过但已经忘记了,所以就不得不去看书,自己从中也收获了不少新的知识,让我在东海科技学院学到的知识有所用。同时,这次设计的顺利完成也离不开指导老师的帮助。总得来说,此次设计使我更深刻、更系统的掌握了关于给排水设计这方面的知识,也使我摸索到给排水设计要点,更清晰了解整个设计过程。相信本人在以后的工作过程中遇到类似的问题,应该能很快地解决40 本科毕业论文译文[参考文献][1]陈耀宗、姜文源编著《建筑给水排水设计手册》[M].1992年12月中国建筑工业出版社.[2]核工业第二研究设计院《给水排水设计手册》[M].第一册1986年12月中国建筑工业出版社.[3]核工业第二研究设计院《给水排水设计手册》[M].第二册1986年12月中国建筑工业出版社.[4]全国民用建筑工程设计技术措施[M].2009年版给水排水/住房和城乡建设部工程质量安全监管司,中国建筑标准设计研究院编.北京:中国计划出版社,2009.[5]中国市政工程华北设计院《给水排水设计手册》[M].第十册1986年12月中国建筑工业出版社.[6]中国建筑标准设计研究所《自动喷水灭火系统设计规范GB50084-2001》[S].2005中国计划出版社.[7]中国建筑标准设计研究所《给排水设计规范》[S].2003中国计划出版社.[8]王增长、曾雪花《建筑给水排水工程》[M].1990年6月中国建筑工业出版社.[9]中国建筑标准设计研究所《全国通用给水排水图集》[S].1994年工业出版社.[10]《给水排水标准图集合定本》[S].中国建筑标准设计研究院.[11]NationalStandardPlumbingCode[J].Washington,DC,1984.[12]Harbold,HarryS.SanitaryengineeringProblemsandCalculationsfortheProfessionalEngineer[J].AnnArbor,1979.40'